Excel Test Sdn Bhd
Unit C717, 7th Floor,
Block C, Kelana Square,
17, Jalan SS 7/26,
47301 Petaling Jaya,
Selangor, Malaysia.
+603-7804 6186
+603-7804 4186
ychooimy

DES-P450M High-Level Electrolyzed Disinfectant Generator (NaOCl for Medical)

Previous 2 / 15 Next


High-level Electrolyzed Disinfectant Generator
In-hospital Infection Prevention & Improvement the Care environments "NaOClean"
 
Product Detail
01)Control board - 02)Door handle - 03)Side glass - 04)Magnet or sticking type - 05)Disinfectant outlet part
 
Specifications
Name: 
Model: 
Rating: 

Dimension:
Weight:
Generating:
pH:
Concentration:
Disinfectant Generator 
DES-P450(Medical)
AC 110 or 220V, 50/60Hz,
max. 1100W 
W260 X D560 X H580 mm
about 20kg
1.5~2L/min 
7.05 Neutral
650~700ppm
 
Features of High-level Electrolyzed Disinfectant
1. In-hospital Infection Prevention, Improvement the Care Environments
On-site Mass production of Powerful sterilizing water through electrolysis and High-level disinfection & cleaning within a short time. Meet the Activated free chlorine concentration of 650~675ppm which is Endoscopic Disinfection Criterion.

2. Easy and convenient one-touch automatic production
It can automatically produce a certain concentration with the amount needed as required and can be used directly on-site by one-touch button operation.

3. Significant savings in production
Significant cost savings compared to traditional chemicals by using salt (or HCl). And Less than 1/7 times maintenance cost (based on Cydex OPA). Reduced labour time by shortening cleaning process.

4. Eco-friendly product with safety
There is no danger of using chemicals and no toxic smell, no skin damage caused by chemicals. Even if it is discharged as it is, there is no damage to environment pollution and drainage facilities.
 
 
Applications
  Sterilization of Endoscope

-MRSA, MTB, E.coli, S.aureus, Salmonella, General bacteria, Virus and more 99.9% High-level Sterilization of all kinds of bacteria within 30 sec.

-Effective Removal Biofilm: It is difficult to remove bacterial biofilm on the surface of the endoscope using traditional chemicals, but it is easily and effectively removed with Electrolyzed water.
  Disinfection of Medical instruments

-You can sterilize many kinds of Bacteria on the surface of medical instruments and prevent cross-infection from them.

*Please note that it is recommended that rinse with tap water once after sterilization with NaOClean solution to prevent of corrosion.
 
Basic Principle
This system ensures the reliable supply of electrolyzed disinfectant based highly active Sodium hypochlorite. Without affecting the pH level, just electric current passes through tap water mixed with a small amount of salt in an undivided electrolytic bath. Then the machine generates sodium hypochlorite water while keeping the constant level. 

Meet the Activated free chlorine concentration of 650 ~ 675ppm which is Endoscopic Disinfection Criterion (650 ~ 1000ppm Adjustable)